We’re pleased to announce that part number DU-1 2 of Transformer Power under FSC 5950 Coils and Transformers with NSN 5950005202693 by Signal Transformer Co Inc is now available and in stock. If you’d like to get a quick quote for part number DU-1 2 with NSN 5950005202693 , fill out the short Request for Quote (RFQ) form below to get started. One of our sales representatives will get back to you with your quote in 15 minutes or less.
It’s important that you fill out all fields, especially the asterisk-marked (*) ones like Need Parts By and Quantity (ea) carefully and completely. Your response to these fields will determine the bulk of your quote.
The National Stock Number or NATO Stock Number (NSN) is a 13-digit serial number assigned by the Defense Logistics Agency (DLA) to all items that are procured, stocked, and issued through the federal supply system. Used by all member states of the North Atlantic Treaty Organization (NATO), the NSN makes cataloging and organizing items and parts easy. If you would like to learn more about NSN 5950005202693, or would like to request a quote for DU-1 2 NSN part, feel free to call us at our toll-free number, +1-714-705-4780, or email us at sales@asapaxis.com.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-520-2693 Item Description: Transformer Power | 5950 | 005202693 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Du-1 2 | 2 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 5.312 INCHES MAXIMUM5.312 INCHES MAXIMUM5.312 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 5.250 INCHES MAXIMUM5.250 INCHES MAXIMUM5.250 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 5.312 INCHES MAXIMUM5.312 INCHES MAXIMUM5.312 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.196 INCHES NOMINAL SINGLE GROUP0.196 INCHES NOMINAL SINGLE GROUP0.196 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 500.0 HERTZ MAXIMUM SINGLE COMPONENT500.0 HERTZ MAXIMUM SINGLE COMPONENT500.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 0.5 KILOVOLT-AMPERE SINGLE COMPONENT0.5 KILOVOLT-AMPERE SINGLE COMPONENT0.5 KILOVOLT-AMPERE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | OPENOPENOPEN |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND SLOT SINGLE GROUPSLOT SINGLE GROUPSLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 4.6 AMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY AND 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 16 THREADED STUD |
ASAP Axis, owned and operated by ASAP Semiconductor, has a vast inventory of DU-1 2 NSN part. As an AS9120B, ISO 9001:2015, and FAA AC 0056B accredited member of the Aviation Suppliers Association (ASA), we’re proudly serving companies in the aerospace, aviation, and defense industries around the world. Your order of part number DU-1 2 will ship from any of our advanced shipping facilities in California, Illinois, Nevada, Pennsylvania, Oregon, Minnesota, Arizona, New York, Virginia, Washington, Wisconsin, New Mexico and Massachusetts. We’ve also recently opened offices in Alberta, Canada.
We Hope You Choose Us as Your Trusted, High-Quality Parts Distributor In The Future.
Request for Quote